<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-16 22-53-16
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 55 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 71 kHz 15026 6,1427
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,7 dBr 5,29 dBr 5,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 71 kHz MIN: 12 kHz % above 76 kHz: 6,1427 Acquired: 2025/07/16 22.52.13 Total samples: 15026 Equivalent time: 0:12:31 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 5,8 dBr MIN: 4,7 dBr AVE: 5,29 dBr % above 12,2 dBr: 0,0 Last value: 5,4 dBr (2025/07/16 22.52.12) 22.38 22.40 22.42 22.44 22.46 22.48 22.50 22.52 0 2 4 6 Pm [dBr]